Mortar and Grout: Inspecting for Grout and Rebar - After the Wall is Built

The inspector didn’t show up on the job but you kept building – now you are being told to tear down the wall because no one knows if the rebars are in the right place and if the grout is solid. What do you do now?

Luckily you have some nondestructive options for “post-construction inspection.” Some methods are very simple, while others are high-tech and require expensive equipment with experienced operators. If you hire someone to evaluate your wall make sure they have good masonry experience. Many test labs are used to scanning reinforced concrete and can get confused by all the complexity of a masonry wall.

Sounding (tapping on the wall with a hammer) can be used to find solid grouted cells and near-surface voids.
Sounding (tapping on the wall with a hammer) can be used to find solid grouted cells and near-surface voids.

If you have a good ear, sounding (tapping on the wall with a hammer) can be used to find solid grouted cells and near-surface voids. If you want to verify your findings, just drill a small hole to see if you hit solid grout or a void. Drill into mortar joints to simplify repairs.

A pachometer is used to find metals in walls.
A pachometer is used to find metals in walls.

A pachometer (fancy metal detector) is used to find metals in walls, including veneer anchors, rebar, joint reinforcement, conduit, pipes, etc. Pachometers used for scanning reinforced concrete are good at finding bars up to 5 or 6 inches deep in the wall. The more expensive pachometers can tell bar size and depth of bars within walls.

Surface penetrating radar is sensitive to metals and can also be used to find solid grout and voids deep within masonry walls.
Surface penetrating radar is sensitive to metals and can also be used to find solid grout and voids deep within masonry walls.

Surface penetrating radar is sensitive to metals (such as rebar) and can also be used to find solid grout and voids deep within masonry walls. Scanning is carried out by rolling a radar antenna over the wall and interpreting reflections from metals, grout, voids, and other internal anomalies.

Infrared imaging using an infrared camera is a quick way to locate grouted cells in masonry walls.
Infrared imaging using an infrared camera is a quick way to locate grouted cells in masonry walls.

If temperature conditions are right, infrared imaging using an infrared camera is a quick way to locate grouted cells in masonry walls. A temperature differential of 20 to 30 degrees from one side of the wall to the other usually gives good results. This image is of a partially grouted wall was heated by strong sunlight for about 3 hours. Grouted cells have high thermal mass and take longer to heat up than empty areas.

Strength, Style, and Staying Power: The Impact of Stone Veneer in Commercial Design
October 2025

Stone has always signified strength, permanence, and sophistication. In commercial environments, those qualities go beyond design and directly shape how a business is perceived. A lobby, storefront, or even a single feature wall can become the first chapt

Bonding with Masonry: 2025 Q3
October 2025

This issue’s questions come from an Engineer and an Architect. What questions do you have? Send them to info@masonrymagazine.com, attention Technical Talk. Q. An Engineer asked when the reinforcement for the masonry diaphragm chords must be continuous th

Spherical Block LLC Continues Silver MAP Partnership in 2026
October 2025

The Mason Contractors Association of America (MCAA) is happy to announce that Spherical Block LLC has renewed its Silver Partnership for the 2026 Masonry Alliance Program.

EZG Manufacturing Renews its Cornerstone Partnership in 2026
October 2025

The Mason Contractors Association of America (MCAA) is delighted to announce that EZG Manufacturing will continue its esteemed Cornerstone partnership in the 2026 Masonry Alliance Program.